Part Number Hot Search : 
EGFZ15D HR002AM LVA519 MAX4391 0074B MJH16004 XXXGX MX621P
Product Description
Full Text Search
 

To Download TFS80D1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 tfs 80D1doc
Version 1.0
06.01.02
VI TELEFILTER
1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 23 C 0 dBm. for input: for output:
Filter Specification
TFS 80 D1 - 1/3
50 0 pF 50 0 pF,
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 80 D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data Insertion loss (Reference level) Centre frequency Pass band (-3 dB) Bandwidth at ambient temperature: 3 dB - band width Relative attenuation fc fc + 200 fc - 400 fc 400 fc 0,5 fc - 1,0 fc + 1,0 arel fc 90 fc + 400 fc - 200 fc 500 fc 1,0 fc - 35 fc + 35 kHz kHz kHz kHz MHz MHz MHz ae
typ. value 15 80,07 dB MHz
tolerance / limit max. 16 80,07 0,02 dB MHz
fc at ambient temperature ( fCAT )
fC- 90 kHz ... fC + 90 kHz
184
kHz
min. 180
kHz
40 52...65 64...70 62...70 4,12
dB dB dB dB s
max. 3 min. 19 min. 14 min. 35 min. 50 min. 60 min. 58 -
dB dB dB dB dB dB dB
kHz kHz kHz MHz MHz MHz
Average group delay in pass band: Group delay ripple: fc - 100 kHz .....fc fc ... fc + 100 kHz Deviation from linear phase (p-p) fc ... fc 100 kHz
300 600
ns ns
max. 600 max. 700
ns ns
5,2 55...60 33...34 20 -0,075 dB dB C ppm/K -
Crosstalk attenuation compared to main signal Triple transit attenuation compared to main signal Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T : *) Operating temperature range Storage temperature range Input power level -
fc(Hz) = Tcf(ppm/K) x (T - To) x fTo(MHz) - 25 C ... + 75 C - 30 C ... + 85 C max. + 10 dBm
* ) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Wadim P. Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 80D1doc
Version 1.0
06.01.02
VI TELEFILTER
Filter Specification
TFS 80 D1 - 2/3
3. Package: 38,10 mm
TFS 80 D1 tft L7
25,4 mm
Pin 4 Pin 6 Pin 17 Pin 15 Pin 12,14,26,28
Input Input RF Return Output Output RF Return Package Ground
5,0 Max 5,00,5 0,450,03 5,08 3,81
4
6
12 14 20,32
28 26 22,86 33,02
17 15
4. 50 matching network: 4 6 12 14
28 26
17
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 80D1doc
Version 1.0
06.01.02
VI TELEFILTER 5. Air reflow temperature conditions
Filter Specification
TFS 80 D1 - 3/3
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec.
Air reflow profile
260 240 220 200 180 160 140 120 100 80 te m pe rat ur e/ 60 40 20 0 0 20 40 60 80 100 120 time / 140 160 180 200 220 240
main-heating periods over 200 C 20 sec. - 25 sec.
peak temperature 255 C 5 C
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 80 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 80 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS80D1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X